Troubleshooting 495
Associated Applications
•
PD (Personal Directory)
Troubleshooting
•
Check that SSD messages containing information required for Unicode
Name Directory lookup are sent from Call Server to Signaling Server
during call.
Enable SSD content printing in LD 77 for specific set TN:
>ld 77
PASS
.dmtn
TN 1 096 0 00 03
See LD77 specification for details.
•
Check UND logs at TPS layer.
Set log level to DEBUG for tSET process using following command:
[nortel@und-pd ~]$ syslogLevelSet tps tSET 7
Find info related to UND feature in TPS logs.
•
Enable Unicode Name Directory DEBUG logs on Application server
configured in LD117. Use the following command for that:
[nortel@und-pd ~]$ nd debugOn
For details see command section of this guide for Unicode Name
Directory feature.
• If Name Directory feature does not work.
— Ensure that Application Server is up and reachable by TPS.
—
Ensure CPND block exists. Use following Call server overlay
command for that.
>ld 95
REQ prt
TYPE cpnd
CUST 0
TYPE CPND
CUST 0
CNFG ALON
MXLN 17
STAL YES
DFLN 13
DES NO
Nortel Communication Server 1000
Troubleshooting Guide for Distributors
NN43001-730 02.02 31 December 2009
Copyright © 2008-2009 Nortel Networks. All Rights Reserved.
.
Kommentare zu diesen Handbüchern