VNS BUG ERR debug tool in PDT 375
The status will keep printing after every 10 seconds.
pdt>sl1crShow 12 5
MAINPM = SPECIAL
AUXPM NCR
AML_MAINT 1
PRA_MSG_CR 2
PRA_ROSE_CR 2
Total AUXPM CR Count = 5
value =0=0x0
The status will keep printing after every 5 seconds.
pdt>sl1crShow 12 37 15
MAINPM = SPECIAL
AUXPM = AML_MAINT
The Call Register count = 1
value =0=0x0
The status will keep printing after every 15 seconds.
pdt> sl1crShowStop
value =0=0x0
pdt> sl1crShowHelp
sl1crShow :
Usage is to be one among the following :
sl1crShow [interval]
sl1crShow [mainpm] [interval]
sl1crShow [mainpm] [auxpm] [interval]
Prints the number of Call Registers for the specified mainpm
and auxpm values at the specified intervals
INPUT: interval - Time interval between successive
printings
[range - 1 to 3600 (seconds)]
mainpm - MAINPM value for corresponding AUXPM printing
[range - 0 to 27]
auxpm - AUXPM value for which the number of Call Registers
will be printed [range - 0 to MAX AUXPM of that MAINPM]
sl1crShowStop - to stop printing the Call Register status.
value =0=0x0
VNS BUG ERR debug tool in PDT
The VNS tool provides extensive diagnostic data to be printed with the
VNS ERROR and VNS BUG. You can use this tool to troubleshoot
various call scenarios involving VNS. With the vnsdebug command on,
detailed information regarding the VNS BUG/ERR prints on the TTY. This
command also ensures that a RAS prints with the VNS ERROR.